BKHDD - FS-251 ENAMEL, ALKYD, SEMIGLOSS OLIVE DRAB, 24084
- MSDS: BKHDD
- Manufacturer: CON LUX COATINGS INC
- Product Name: FS-251 ENAMEL, ALKYD, SEMIGLOSS OLIVE DRAB, 24084
- National Stock Number: 8010-00-081-0809
Product Identification
Product ID:FS-251 ENAMEL, ALKYD, SEMIGLOSS OLIVE DRAB, 24084
MSDS Date:12/27/1989
FSC:8010
NIIN:00-081-0809
MSDS Number: BKHDD
Responsible Party
EDISON, NJ 08818-0847
Emergency Phone: (201) 287-4000
Info Phone: (201) 287-4000
Cage: 60189
Contractor
Telephone: 732-287-4000
Cage: 60189
Ingredients
MINERAL SPIRITS
CAS: 64742-86-7
Fraction By Weight: >1%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: <1%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9192
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 4%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
SILICA AMORPHOUS HYDRATED, SILICEOUS EARTH, FUMED SILICA,
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: >1%
OSHA PEL 80 MG/CUM (%SIO2+2)
ACGIH TLV: 0.2 MG/CUM RESP/DUST
TALC (CONTAINING NO ASBESTOS)
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: >1%
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST; 9192
DIACETONE ALCOHOL (4-HYDROXY-4-METHYL-2-PENTANONE)
CAS: 123-42-2
RTECS: SA9100000
Fraction By Weight: >1%
OSHA PEL 50 PPM
ACGIH TLV: 50 PPM; 9192
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE/INGESTION: IRRITATION.
INHALATION: IRRITATION OF THE RESPIRATORY TRACT, HEADACHE, NAUSEA,
DIZZINESS, PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN/EYE/INGESTION: IRRITATION. INHALATION:
IRRITATION OF THE RESPIRATORY TRACT, HEADACHE, NAUSEA, DIZZINESS,
PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE.
First Aid
First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN:
WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. GIVE CPR OR
OXYGEN IF NEEDED. TREAT SYMPTOMATICALLY. INGESTION: DRINK 1 OR 2
GLASSES OF WATER TO DILUTE. DON'T INDUCE VOMITING. IF SPONTANEOUS
VOMITING OCCURS KEEP HEAD AT OR BELOW KNEE LEVEL TO PREVENT
ASPIRATION INTO LUNGS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:105F
Lower Limits:1%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, & WATER MIST.
Fire Fighting Procedures:SMOTHER FLAMES W/ONE OF THE EXTINGUISHING
MEDIA. WATER MAY BE USED TO COOL DOWN UNOPENED CONTAINERS IN
VICINITY.
Unusual Fire/Explosion Hazard:CONTAINS FLAMMABLE SOLVENT. COMBUSTIBLE
LIQUID.
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. WEAR
APPROPRIATE PERSONAL PROTECTION EQUIPMENT & APPROVED RESPIRATOR.
CONTAIN SPILL W/ABSORBENT MATERIAL & PUT INTO VAPOR TIGHT
CONTAINERS.
Handling
Handling and Storage Precautions:STORE IN APPROPRIATE AREAS. GROUND
CONTAINERS WHEN POURING LIQUIDS & POWDERS TO AVOID STATIC CHARGE
BUILD UP. AVOID SKIN CONTACT.
Other Precautions:PROVIDE ADEQUATE VENTILATION OR RESPIRATORY
PROTECTION TO REMOVE DECOMPOSITION PRODUCTS DURING WELDING OR FLAME
CUTTING COATED SURFACES.
Exposure Controls
Respiratory Protection:IN OUTDOOR OR OPEN AREAS, USE APPROVED
RESPIRATOR TO REMOVE SOLID AIRBORNE PARTICLES OF OVER SPRAY DURING
SPRAY APPLICATION. IN RESTRICTED VENTILATION AREAS USE APPROVED
RESPIRATOR DESIGN TO KEEP THE AIR CONTAMINATE CONCENTRATION
Eye Protection:SAFETY GLASSES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH HANDS BEFORE EATING, SMOKING, OR USING WASHROOM
FACILITIES.
Supplemental Safety and Health
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:148-362F
Vapor Pres:2
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:57.28%
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:EXTREME HEAT, SPARKS, OPEN FLAMES, &
SOURCES OF IGNITION.
Hazardous Decomposition Products:HAZARDOUS FUMES
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS. PREVENT MATERIAL FROM CONTACTING ANY WATER
SOURCES OR SEWERS LEADING TO SURFACE WATERS. COMBUSTIBLE LIQUID.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.